Features:-

  • Suitable for paint and coating, automobile industry.
  • plastic and rubber, construction material, electronic industry, etc.
  • Simulate the full spectrum sun light, ensure the reliability of experimental data
  • Optional irradiance calibrator for calibration of irradiance
  • Feature water cooling lamp and drum-type structure to ensure uniform and stable irradiation
  • Capable of freely programming 10 test programs and storing 6 preset international standard programs
  • Support exporting test data with USB flash drive
  • MATERIAL AGAINST ORDER
Code XAT-A101 XAT-A102 XAT-A103
Xenon arc lamp 6.5kW water cooling long arc xenon lamp
Lifetime of lamp 2000 hours for normal use
Light filter daylight: Type S Boro+Type S Boro window glass: Type S Boro+Soda Lime extended UV: Quartz+Type S Boro
Exposure area 6500cm² (63~65 pcs standard sample panel 150mm×70mm)
Irradiance monitoring point 340nm, 420nm, 300nm~400nm
Irradiance range 0.25W/m²~1.26W/m² (340nm) 0.23W/m²~1.10W/m² (340nm) 0.29W/m²~1.50W/m² (340nm)
0.59W/m²~2.76W/m² (420nm) 0.61W/m²~2.76W/m² (420nm) 0.59W/m²~2.79W/m² (420nm)
29W/m²~141W/m² (300nm~400nm) 28W/m²~129W/m² (300nm~400nm) 32W/m²~161W/m² (300nm~400nm)
Temperature range RT~70°C
BPT/BST range BPT: RT~110°C, BST: RT~110°C
Humidity range light: 10%RH~75%RH, dark: 10%RH~95%RH
Irradiance deviation ±0.02W/m² (340nm, 420nm), ±5W/m² (300nm~400nm)
Temperature deviation ±2°C
Temperature fluctuation ±1°C
BPT/BST deviation ±3°C
Humidity deviation ±5%RH
Rotation speed of sample holder 1r/min
Humidifying method high-pressure atomizing humidification
Purified water consumption 300L~400L (continuous operation for 24 hours)
Material inside: stainless steel plate, outside: corrosion-resistant steel plate with powder coating
Lamp protect over temperature of cooling water, low flow of cooling water, abnormality of lamp power
Alarm function large irradiance error, over temperature of chamber, over temperature of BPT or BST, large humidity error, spraying water shortage, high conductivity of purified water
Cooling water system protect monitor the conductivity of cooling water at real-time
Radiation protect xenon lamp automatically turns off when chamber door opens
Operating environment temperature: 22℃~30℃, humidity: 30%RH~85%RH
Power supply AC380V, 3Φ, 50Hz
Power 9.5kW
Chamber dimension (L×W×H) 780×780×800mm
External dimension (L×W×H) 1200×1200×1970mm
Weight 500kg